X-ray generators
The outstanding characteristics of our XRG series of X-ray generators are compact design, a voltage range from 5 to 225 kV (unipolar) and power ratings up to 1,000 W. State-of-the-art high voltage technology ensures that our generators fulfil the most rigorous requirements for high voltage stability and a long service life.
The XRG series X-ray generators consist of two modules: the XCM control module the HVM high voltage module. Safety is always the top priority; the power supplies for high voltage generation and for the internal electronics are fed separately. This enables safe switch-off of the high voltage while maintaining communication.
Robust construction makes it possible to install the generators in any situation; installation on moving platforms or above head height is also possible. The modular concept enables adaptations to meet specific customer needs and requirements
Activation and diagnosis via an Ethernet connection are available for every X-ray generator. On request, we offer either our own IMS operating software or an API for integration into your own software environment.
Our generators have been developed for extreme conditions of use; today they are successfully used in the following application areas:
- Thickness measurement (particularly in the steel industry)
- Inspection of food products
- Radiometric and radiographic testing of components
- Sorting applications
- and many more.
High stability and measurement accuracy with network connection
Robust and durable design thanks to stainless steel housing
Individual advice concerning technical and economic aspects
Performance overview
- State-of-the-art high voltage technology with infinitely variable adjustment ranges from 5 to 320 kV
- Input voltage range 90 to 250 V AC
- Network connection for control and diagnosis
- High stability and accuracy
- Robust design thanks to stainless steel housing
- Compact construction
- CE conformity
- Produced in compliance with DIN EN ISO 9001: 2015
Request a personal consultation appointment now
Simply use our Contact Form to request a consultation appointment. Provide some information about your subject of interest, and we will get back to you as quickly as possible.
We look forward to your enquiry!

XRG 040/200/01
- Water-cooled
- High voltage adjustment range: 5 to 40 kV
- Emission adjustment range: 0-10 mA
- Maximum power: 200 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 5 A, single-phase, 50/60 Hz
- High voltage connection: CA11
- Dimensions: 276 x 173 x 225 mm
- Weight: 10.5 kg
- Download datasheet

XRG 075/1000
- Water-cooled
- High voltage adjustment range: 5 to 75 kV
- Emission adjustment range: 0-17.5 mA
- Maximum power: 1000 W
- Mains voltage for high voltage generation: 180 to 250 V AC, 8 A, single-phase, 50/60 Hz
- High voltage connection: CA11
- Dimensions: 380 x 130 x 255 mm
- Weight: 15 kg
- Download datasheet

XRG 100/1000
- Water-cooled
- High voltage adjustment range: 5 to 100 kV
- Emission adjustment range: 0-17.5 mA
- Maximum power: Mains voltage > 180 V = 1000 W | > 90 V = 500 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 10 A, single-phase, 50/60 Hz
- High voltage connection: R10
- Dimensions: 416 x 171 x 350 mm
- Weight: 21 kg
- Download datasheet

XRG 100/1000/01
- Water-cooled
- High voltage adjustment range: 5 to 85 kV
- Emission adjustment range: 0-17.5 mA
- Maximum power: Mains voltage > 180 V = 1000 W | > 90 V = 500 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 10 A, single-phase, 50/60 Hz
- High voltage connection: CA11
- Dimensions: 416 x 171 x 350 mm
- Weight: 21 kg
- Download datasheet

XRG 225/1000
- Water-cooled
- High voltage adjustment range: 20 to 225 kV
- Emission adjustment range: 0-10 mA
- Maximum power: Mains voltage > 180 V = 1000 W | > 90 V = 500 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 10 A, single-phase, 50/60 Hz
- High voltage connection: R28
- Dimensions: 645 x 171 x 462 mm
- Weight: 40 kg
- Download datasheet

XRG 450/2000
- Water-cooled
- High voltage adjustment range: 40 to 450 kV
- Emission adjustment range: 0-10 mA
- Maximum power: Mains voltage > 180 V = 2000 W | > 90 V = 1000 W
- Mains voltage for high voltage generation: 2 x 90 to 250 V AC, 10 A, single-phase, 50/60 Hz
- High voltage connection: R28
- Dimensions: 2x 645 x 171 x 462 mm
- Weight: 2 x 40 kg (80kg)
- Download datasheet

XRG 160/320/02
- Air-cooled
- Einstellbereich Hochspannung: 5-160 kV
- Emission adjustment range: 0-3 mA
- Maximum power: 320 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 4 A, single-phase, 50/60 Hz
- High voltage connection: R24
- Dimensions: 494 x 182 x 401 mm
- Weight: 34 kg
- Air-cooled generators are designed not to require a cooler or cooling connection
- Download datasheet

XRG 160/320/04
- Air-cooled
- Anode generator
- High voltage adjustment range: 5 to 160 kV
- Emission adjustment range: 0-3 mA
- Maximum power: 320 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 4 A, single-phase, 50/60 Hz
- High voltage connection: R24
- Dimensions: 494 x 182 x 401 mm
- Weight: 34 kg
- Air-cooled generators are designed not to require a cooler or cooling connection
- Download datasheet

XRG 320/640
- Air-cooled
- Bipolar system with anode and cathode X-ray generator
- High voltage adjustment range: 10 to 320 kV
- Emission adjustment range: 0-3 mA
- Maximum power: 640 W
- Mains voltage for high voltage generation: 90 to 250 V AC, 4 A, single-phase, 50/60 Hz
- High voltage connection: 2x 24
- Dimensions: 2 x 494 x 182 x 401 mm
- Weight: 2 x 34 kg = 68 kg
- Air-cooled generators are designed not to require a cooler or cooling connection
- Datasheet XRG 160/320/02 (Cathode generator)
- Datasheet XRG 160/320/04 (Anode generator)
No suitable components found?
Briefly explain what you are looking for. Together we will find the right solution.
Find the right system in three steps. An expert will contact you.
Other products
In our versatile product range we offer different types of components.
Return to Product overview.